400W C400 SERIES

Product View

External View

DH-C400-05
 DH-C400-12
 DH-C400-15
 DH-C400-24
 DH-C400-36
 DH-C400-48

SMALL SIZE
LOW LINE & LOAD REGULATION
HIGH EFFICIENCY
LOW OUTPUT RIPPLE & NOISE
SAFETY DESIGN MEETS TO UL, FCC, VDE STANDARDS
MODELC400-12C400-15C400-24C400-36C400-48
INPUTVOLTAGEAC 90 ~ 130 180~260V
FREQUENCY47 ~ 440
INRUSH CURRENT30A(110V AC INPUT), 50A(230V AC INPUT)
OUTPUTVOLTAGE (V)1215243648
CURRENT (A)33.026.616.711.18.3
LINE REGULATION (%)0.8 MAX (90 ~ 260V)
LOAD REGULATION (%)0.9 MAX (0 ~ 100%)
VOUT ADSUSTABLE RANGE (%)VOUT x 10 (Typ)
TEMP. COEFFICIENT (%) 10.03 (0 ~ +50)
HOLD-UP TIME20 (MIN)
RIPPLE / NOISE (mV P-P)VOUT x 1% (MAX)
OUTPUT
PROTECTIONS
OVER CURRENT PROTECTION130~180% OF RATED IOUT(AUTOMATIC RECOVERY)
OVER VOLTAGE PROTECTION120~140% OF RATED VOUT(SHUT DOWN LATCH)
EFFICIENCY75% (TYP)
OPERATING TEMPERATURE ()-10 ~ +50 (AT FULL RATED LOAD)
STORAGE TEMPERATURE ()-20 ~ +75 (MIN)
OPERATING HUMIDITY (%)10 ~ 90RH (NON CONDENSING)
TURN ON RESPONS (mS)300 (MAX)
WITHSTAND VOLTAGE (INPUT CHASSIS, INPUT OUTPUT) : 1.5KVAC 1MINUTE
ISOLATION RESISTANCE (OUTPUT CHASSIS) : 100M BY 500V DC MEGGER