750W C750 SERIES

Product View

External View

DH-C750-05
 DH-C750-12
 DH-C750-15
 DH-C750-24
 DH-C750-36
 DH-C750-48

SMALL SIZE
LOW LINE & LOAD REGULATION
HIGH EFFICIENCY
LOW OUTPUT RIPPLE & NOISE
SAFETY DESIGN MEETS TO UL, FCC, VDE STANDARDS
MODELC750-05C750-12C750-15C750-24C750-36C750-48
INPUTVOLTAGEAC 90 ~ 130 180~260V
FREQUENCY47 ~ 440
INRUSH CURRENT30A(100V AC INPUT), 60A(220V AC INPUT)
OUTPUTVOLTAGE (V)51215243648
CURRENT (A)15062.5503120.815.6
LINE REGULATION (%)0.5 MAX
LOAD REGULATION (%)0.9 MAX
VOUT ADSUSTABLE RANGE (%)VOUT x 10 (Typ)
TEMP. COEFFICIENT (%) 10.05 (0 ~ +50)
HOLD-UP TIME20 (MIN)
RIPPLE / NOISE (mV P-P)VOUT x 1% (MAX)
OUTPUT
PROTECTIONS
OVER CURRENT PROTECTION130~180% OF RATED IOUT(AUTOMATIC RECOVERY)
OVER VOLTAGE PROTECTION120~140% OF RATED VOUT(SHUT DOWN LATCH)
EFFICIENCY75% (TYP)
OPERATING TEMPERATURE ()-10 ~ +50 (AT FULL RATED LOAD)
STORAGE TEMPERATURE ()-20 ~ +75 (MIN)
OPERATING HUMIDITY (%)10 ~ 90RH (NON CONDENSING)
TURN ON RESPONS (mS)300 (MAX)
WITHSTAND VOLTAGE (INPUT CHASSIS, INPUT OUTPUT) : 1.5KVAC 1MINUTE
ISOLATION RESISTANCE (OUTPUT CHASSIS) : 100M BY 500V DC MEGGER