DH-P100-MAB

MODEL | P100-MAB | ||||||
INPUT | VOLTAGE | AC 90 ~ 130V or 180V ~ 264V (AUTO SELECT) | |||||
FREQUENCY | 47 ~ 63 | ||||||
INRUSH CURRENT | 30A MAX | ||||||
OUTPUT | VOLTAGE (V) | +3.3 | +5 | +12 | |||
CURRENT (A) | 14 | 5 | 1 | ||||
LINE REGULATION (%) | 0.9 MAX (0% ~ 100%) | ||||||
TEMP. COEFFICIENT (%) 1 | 0.03 (0 ~ +50) | ||||||
HOLD-UP TIME | 20 (MIN) | ||||||
RIPPLE / NOISE (mV P-P) | VOUT x 1% (MAX) | ||||||
OUTPUT PROTECTIONS | OVER CURRENT PROTECTION | 130~180% OF RATED IOUT(AUTOMATIC RECOVERY) | |||||
OVER VOLTAGE PROTECTION | 120~140% OF RATED VOUT(SHUT DOWN LATCH) | ||||||
EFFICIENCY | 75% (TYP) | ||||||
OPERATING TEMPERATURE () | -10 ~ +50 (AT FULL RATED LOAD) | ||||||
STORAGE TEMPERATURE () | -20 ~ +75 (MIN) | ||||||
OPERATING HUMIDITY (%) | 10 ~ 90RH (NON CONDENSING) | ||||||
TURN ON RESPONS (mS) | 100 (MAX) | ||||||
WITHSTAND VOLTAGE (INPUT ![]() ![]() | |||||||
ISOLATION RESISTANCE (OUTPUT ![]() |