DH-L55-ABB

MODEL | L33-ABB | L33-ACC | |||||
INPUT | VOLTAGE | AC 90 ~ 260V (FREE VOLTAGE) | |||||
FREQUENCY | 47 ~ 440 | ||||||
INRUSH CURRENT | 20A(110V AC INPUT), 40A(220V AC INPUT) | ||||||
OUTPUT | VOLTAGE (V) | +5 | +12 | -12 | +5 | +12 | -12 |
CURRENT (A) | 3.0 | 1.0 | 0.5 | 5.0 | 2.0 | 0.5 | |
LINE REGULATION (%) | 0.8 MAX (90 ~ 260V) | ||||||
LOAD REGULATION (%) | 5V (5%) 12V, 5V (10%) CROSS REGULATION | ||||||
VOUT ADSUSTABLE RANGE (%) | VOUT x 10 (Typ) | ||||||
TEMP. COEFFICIENT (%) 1 | 0.03 (0 ~ +50) | ||||||
HOLD-UP TIME | 20 (MIN) | ||||||
RIPPLE / NOISE (mV P-P) | VOUT x 1% (MAX) | ||||||
OUTPUT PROTECTIONS | OVER CURRENT PROTECTION | 130~180% OF RATED IOUT(AUTOMATIC RECOVERY) | |||||
OVER VOLTAGE PROTECTION | 120~140% OF RATED VOUT(SHUT DOWN LATCH) | ||||||
EFFICIENCY | 75% (TYP) | ||||||
OPERATING TEMPERATURE () | -10 ~ +50 (AT FULL RATED LOAD) | ||||||
STORAGE TEMPERATURE () | -20 ~ +75 (MIN) | ||||||
OPERATING HUMIDITY (%) | 10 ~ 90RH (NON CONDENSING) | ||||||
TURN ON RESPONS (mS) | 100 (MAX) | ||||||
WITHSTAND VOLTAGE (INPUT ![]() ![]() | |||||||
ISOLATION RESISTANCE (OUTPUT ![]() |